People AC/DC Contactor Auto Recloser Household/Factory Rdc5-6511 36~380V Magnetic Contactor Manufacturer with CE Humanized Design
Package size per unit product 35.00cm * 25.00cm * 20.00cm Gross weight per unit product 1.200kg Product Description PEOP
Send your inquiryDESCRIPTION
Basic Info
Model NO. | RDC5-6511 |
Arc-extinguishing Medium | Air |
Installation | Fixed |
Structure | AC Contactor |
Poles Number | 3 |
Type | AC Contactor |
Function | Contactor |
Certification | ISO9001-2000, CE, CB, CCC |
Customization | Available |
Transport Package | Export Packaging |
Specification | 6A 9A 12A 18A 25A 32A 38A 40A 50A 65A 80A 95A |
Trademark | PEOPLE |
Origin | Zhejiang, China |
HS Code | 8536200000 |
Production Capacity | 800000 Set/Sets Per Week |
Packaging & Delivery
Package size per unit product 35.00cm * 25.00cm * 20.00cm Gross weight per unit product 1.200kgProduct Description
PEOPLE Brand RDC5 AC/DC Contactor 3P Rated Current 6A-95ARDC5 series AC contactors are mainly used in circuits with AC 50hz, rated working voltage up to 690v, and rated working current up to 95A, for long-distance connection and segmented circuits, and can be directly plugged with thermal relays to form electromagnetic starters , to protect circuits that may be overloaded by operation. The contactor can also be assembled with accessories such as building block auxiliary contact group, air delay head, mechanical interlocking mechanism, etc., to form a delay contactor, a contactor, and a star-delta starter.Product standard: GB/T 14048.4, IEC60947-4-1 and other national standardsMain technique parameter of contactor
Model | RDC5-06 | RDC5-09 | RDC5-12 | RDC5-18 | RDC5-25 | RDC5-32 | RDC5-38 | RDC5-40 | RDC5-50 | RDC5-65 | RDC5-80 | RDC5-95 | ||
Number of pole | 3 poles | |||||||||||||
Rated insulation Voltage(Ui)V | 690 | |||||||||||||
Rated operating Voltage(Ue)V | 380/400,660/900 | |||||||||||||
Conventional heating current(Ith)A | 16 | 20 | 20 | 25 | 32 | 40 | 40 | 50 | 60 | 80 | 110 | 110 | ||
Rated current(Ie)A | AC-3 | 380/400v | 6 | 9 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 |
660/690v | 3.8 | 6.6 | 8.9 | 12 | 18 | 22 | 22 | 34 | 39 | 42 | 49 | 49 | ||
380/400v | 2.6 | 3.5 | 5 | 7.7 | 8.5 | 12 | 14 | 18.5 | 24 | 28 | 37 | 44 | ||
660/690v | 1 | 1.5 | 2 | 3.5 | 4.4 | 7.5 | 8.9 | 9 | 12 | 14 | 17.3 |
Normal operating condition andinstallation condition3.1Ambienttemperature:+5ºC~+40ºCaverage temperature within 24h does notexceed+35ºC3.2Altitude:doesnotexceed2000m3.3 Atmospheric condition:when the highest temperature is +40ºCthe relatively humidity does not exceed 50%;it can allow relatively high humidity when it is at relatively low temperature, for instance, it reaches 90% when it is at +20ºCit should take measurement when there havecondensation occurred due tothetemperaturevariation.3.4Pollutiongrade:33.5Installation category:III3.6 Installation position: the gradient of the mounting surface to the vertical surface does not exceed ±5°3.7 lmpact and vibration: product should be installed and used at the places without obvious shake impactandvibration.
LEADING Series-RDC5 AC contactor
FAQ
Q: If I am interested in your MCB, when can I receive your quotation and details after sending the enquiry?A: All your inquiries will be answered within 8 hours
Q: Can I get samples before placing an order? Because I really don't know if your company's products are of good quality or not.A: Certainly! We also believe that sample orders are the best way to prove quality. Welcome to inquire about the products you wantQ: What are your terms of trade?
A: We accept exw, fob, cif, fca, etc
Q: How long is the delivery time?
A: Sample order usually takes 3-5 working days, formal order usually takes 10-20 days
Q: how to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming,we'll make a satisfied solution for you whin 3 days