IntroductionThe DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at

Send your inquiry

DESCRIPTION

Basic Info
Model NO. DAM1-160
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification ISO9001-2000, CE, CB, CCC, Kema, Asta, Semko, RoHS
Cover BMC Unflaming Material
Base BMC Unflaming Material
Terminal with Terminal Box
Neutral Pole Left Side
Rated Insulation Voltage 1000V
Rated Operation Voltage 400/415V
Transport Package Carton
Specification 16, 20, 25, 32, 40, 50, 70, 80, 100, 125, 160A
Trademark CDADA, OEM, ODM
Origin Shanghai, China
HS Code 8536200000
Production Capacity 40000PCS/Month
Product Description

IntroductionThe DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of electric circuit parts. They are designed for use in electric units having the operative voltage limited to 400V per rated current from 12,5 to 1600A. They correspond to the requirements of EN 60947-1, EN 60947-2 Thermal-Magnetic Circuit Breakers:Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing through the breaker. Because, increase of current means increase of heat. In this way, over current protection function of the breaker is fulfilled by bimetal at load currents higher than the rated current Magnetic protection function (For protection under short circuit conditions) Another function of the breaker is to protect the connected circuit against short circuits. Short circuit may occur as a result of contact of phases with each other or contact of phase-ground. Since a very high current shall pass through the cables in case of short circuit, system energy should be broken in a shorter time due to thermal protection. Breaker should perform instant opening to protect load it is connected to. The part fulfilling this function is a mechanical opening mechanism that operates with magnetization caused by the magnetic area formed by the short circuit current
Thermal-Magnetic fixed type Circuit Breakers
ModelDAM1-160
Breaking Capacity CodeBNS
Rated Current of Frame size- Inm (A)160A
Rated Current-In(40,50 or 55ºC) (A)10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz (V)750V
Rated operation Voltage -Ue(a.c.) 50-60Hz (V)400/415V
Number of Pole3P / 4P
Rated ultimate short Circuit breaking Capacity kA Icu AC400V/50Hz O-CO (KA)253550
Rated service short Circuit breaking Capacity kA Ics AC400V/50Hz O-CO-CO (KA)12.526.2537.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO (KA)41/0.373.5/0.25110/0.25
Rated impulse withstand Voltage -Uimp (V)8000
Dielectric Propery (V)3000
lonization distance (mm)≤30/0
EnduranceTotal Cycles8000
Electrical Life1000
Mechanical Life7000
Over Current tripThermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2)Main circuitA/0
Auxiliary circuitAC-15
Under Voltage Release
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism
DIN clips
Terminal cover
Phase seperator
Extention Handle -
W (mm)3P90
4P120
L (mm)3P120
4P120
H (mm)3P70
4P70
WeightFixed version 3P/4P1.2/1.6
Plug-in version 3P/4P1.4/1.8
Draw out version 3P/4P-

MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification

MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification

MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification

MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification

MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification